Deye Solar inverters
Deye SUN-5K-SG05LP1-EU
Single-phase low-voltage hybrid inverter with two MPPTs
View detailsSolar inverters
Split-phase hybrid inverter, 10 kW
Important: the model is labelled “12 kW”, but its table specifies 10,000 W / 10,000 VA. Pending manufacturer confirmation, the tabulated 10 kW rating is used. A PV and low-voltage battery inverter for 120/240 V or 120/208 V systems. Not intended for direct connection to Ukrainian 230/400 V grids.
MesPal
Key factory specifications from the manufacturer’s brochure.
| Rated output power | 10000 W |
|---|---|
| Rated apparent power | 10000 VA |
| AC output voltage | 120 (L–N); 208 / 240 (L–L) V AC |
| Grid voltage range | 105.5–132 V per phase |
| Rated output current | 41.7 A per phase |
| Power factor | 0.9 lagging…0.9 leading |
| Maximum efficiency | 96% |
| Grid compatibility | Split-phase 120/240 V or 120/208 V; not a direct replacement for 230/400 V grids |
| Maximum PV power | 12000 W |
|---|---|
| Maximum PV voltage | 600 V DC |
| PV startup voltage | 120 V |
| MPPT voltage range | 120–550 V |
| MPPT channels | 2 |
| Maximum PV input current | 18 A per MPPT; table also states MAX 30 A |
| Initial grid feed-in voltage | 160 V |
| Grid voltage range | 85–140 V per phase |
|---|---|
| Maximum bypass current | 60 A |
| Nominal voltage | 85 / 90 V per phase: startup / recovery |
| Nominal battery voltage | 48 V DC |
|---|---|
| Battery operating voltage | 40–62 V DC |
| Maximum PV charging current | 200 A |
| Maximum AC charging current | 200 A |
| Combined AC + PV charging current | 200 A |
| Maximum charging power | 10000 W |
| Maximum efficiency | 91% in battery mode |
| Ingress protection | IP65 |
|---|---|
| Dimensions | 215.5 × 515 × 800 mm (D × W × H) |
| Net weight | 49.8 kg |
| Operating temperature | −25…+60 °C; derating above +45 °C |
| Parallel operation | Up to 6 units |
| Communication interfaces | RS232 / RS485 / Wi-Fi / USB |
| Manufacturer-listed standards | UL 1741 SA/SB; IEEE 1547.1:2020; IEEE 1547:2018; FCC Part 15 |
| Protection functions | Arc-fault detection AFCI; rapid shutdown RSD; PV surge protection |
| Manufacturer-listed standards | NEC 250.15 / 690.5 / 690.12 / 690.11 |
Important: the model is labelled “12 kW”, but its table specifies 10,000 W / 10,000 VA. Pending manufacturer confirmation, the tabulated 10 kW rating is used. The AP0 series uses an American split-phase configuration. Grid voltage, earthing, transformers and protection require an engineered design. The manufacturer lists AFCI and RSD. Listed standards are catalogue declarations, not Vezemo verification of certificates.
Start with a consultation
Describe your task. We will respond within 24 hours with practical next steps.