MesPal MP-BCU

Industrial BMS master controller

A battery system controller measuring up to 1500 V DC, ±500 A and temperature. SOC/SOH/SOE estimation, CAN, RS485 and Ethernet.

Battery voltage measurement range0–1500 V DC
Current measurement range±500 A
Temperature channels64
Supply voltage9–32 V DC

MesPal

Technical specifications

Key factory specifications from the manufacturer’s brochure.

Measurement and balancing

Battery voltage measurement range0–1500 V DC
Voltage measurement accuracy±0.5%
Current measurement range−500…+500 A
Current measurement accuracy±0.5%
Temperature measurement range−40…+125 °C
Temperature channels64
Temperature accuracy±1 °C
Insulation resistance measurement0–10 MΩ; 15% accuracy

Supply, management and communication

Supply voltage9–32 V DC
Power supply outputs5 V / 300 mA; 12 V / 300 mA
Digital inputs8 channels, 0–32 V DC
Digital outputs8 channels, 0–32 V DC
CAN interfaces3 channels; 125 / 250 / 500 kbit/s
RS485 interface1 isolated channel; 1200 / 9600 / 115200 bit/s
Communication interfacesCAN / RS485 / Ethernet

Vezemo verified

Sourcing and delivery under one contract

MP-BCU collects measurements, estimates SOC/SOH/SOE, processes alarms and communicates with the energy system. The manufacturer supports Bootloader, OTA or CAN updates. Integration with monitoring modules and external power protection requires a BMS design. The ambiguous LIN entry listing 10/100 Mbit/s has not been treated as a confirmed specification.

Start with a consultation

Write to us

Describe your task. We will respond within 24 hours with practical next steps.

By submitting this form, you consent to the processing of the provided contact details so we can respond to your request.