A battery system controller measuring up to 1500 V DC, ±500 A and temperature. SOC/SOH/SOE estimation, CAN, RS485 and Ethernet.
Battery voltage measurement range0–1500 V DC
Current measurement range±500 A
Temperature channels64
Supply voltage9–32 V DC
MesPal
Technical specifications
Key factory specifications from the manufacturer’s brochure.
Measurement and balancing
| Battery voltage measurement range | 0–1500 V DC |
|---|---|
| Voltage measurement accuracy | ±0.5% |
| Current measurement range | −500…+500 A |
| Current measurement accuracy | ±0.5% |
| Temperature measurement range | −40…+125 °C |
| Temperature channels | 64 |
| Temperature accuracy | ±1 °C |
| Insulation resistance measurement | 0–10 MΩ; 15% accuracy |
Supply, management and communication
| Supply voltage | 9–32 V DC |
|---|---|
| Power supply outputs | 5 V / 300 mA; 12 V / 300 mA |
| Digital inputs | 8 channels, 0–32 V DC |
| Digital outputs | 8 channels, 0–32 V DC |
| CAN interfaces | 3 channels; 125 / 250 / 500 kbit/s |
| RS485 interface | 1 isolated channel; 1200 / 9600 / 115200 bit/s |
| Communication interfaces | CAN / RS485 / Ethernet |
Sourcing and delivery under one contract
MP-BCU collects measurements, estimates SOC/SOH/SOE, processes alarms and communicates with the energy system. The manufacturer supports Bootloader, OTA or CAN updates. Integration with monitoring modules and external power protection requires a BMS design. The ambiguous LIN entry listing 10/100 Mbit/s has not been treated as a confirmed specification.